  1. Number:        A2TH082290U387
  2. Subject:       Mitronics Machine With Cache Gets Abend
  3. Date:          October 2, 1990
  4. - - - - - - - - - - - - - - - - - - - - - - - - - - - -
  5.  
  6. PROBLEM:       While running NetWare 386 v3.0 (may also happen with v3.1), 
  7.                a Mitronics 386/33 with 64K RAM cache would frequently get
  8.                the message "Abend: Invalid opcode interrupt".  This only
  9.                happened with the RAM cache enabled.  A Mitronics 386/25
  10.                with 32K RAM cache did not have that problem.
  11.  
  12.                Any ideas why the RAM cache caused problems.  Do other
  13.                machines with 64K RAM cache have problems?
  14.  
  15. SOLUTION:      We have seen this with some of the ALR Flexcache machines.
  16.                In general it is always good to disable the caching on
  17.                machines that do their own caching to ensure that it does
  18.                not conflict with the caching that NetWare is doing.  When
  19.                everything is up and running, they can try enabling it to
  20.                see if they get any problems.
  21.  
  22.                (X)    This information was verified verbally
  23.  
  24.